Wisconsin UST Operator Training | Class A/B & C

UST training in Wisconsin is required by federal law and is intended to ensure that those who own and operate underground storage tanks understand how to operate and maintain UST systems properly.

As required by the EPA, all UST operators must be trained by October 13, 2018. After this date, new Class A and B operators must be trained within 30 days of assuming duties. Class C operators must be trained before assuming duties. This applies to the entire state of Wisconsin as well as other states.

In 2015, the EPA revised the UST regulations which includes minimum training requirements for owners and operators of UST systems. Training is required per operator class:

  • Class A training is required for person(s) having primary responsibility for on-site operation and maintenance of UST systems (owner or operator of a UST facility).
  • Class B training is required for persons involved with daily on-site operation and maintenance of UST systems.
  • Class C training is required for daily on-site employees having primary responsibility for addressing emergencies presented by a spill or release from a UST system.

Wisconsin UST Operator Training Courses

Wisconsin UST Class A/B Operator Training

Wisconsin Class A operators have primary responsibility for on-site operation and maintenance of a UST facility. This individual is generally the owner of the station or the designee. For large corporations, this person is the manager or designee responsible for tank operations.

Wisconsin Class B operators have responsibility for the day-to-day aspects of operating, maintaining, and record keeping of a UST facility. This individual (or individuals) is generally the owner or the person/company contracted by the owner to maintain the tanks. For large corporations, this person is the employee, or person/company contracted by the corporation to maintain the tanks.

Description

The UST Class A/B operator training course is presented in chapters. Each chapter utilizes multimedia to enrich the learning experience. Each chapter is followed by a quiz. If the student answers a quiz question incorrectly, the quiz feedback redirects the student to the correct course information.

In addition to the quizzes, the UST Class A/B operator training course includes a final exam of 100 questions, 80% of which must be answered correctly in order to print a certificate.

There is not any time restriction to access the course, so students can complete the entire course in a single session (approximately 4 hours plus exam time) or take the course in segments.

Duration: 4 hours

Purpose & Objective

The purpose of the Underground Storage Tank (UST) Training Program is to protect human health and the environment by preventing future petroleum underground storage tank releases and remediating existing petroleum underground storage tank contamination.

Class A operators must be trained how to manage resources and personnel; maintain compliance with federal, state, and local regulations; ensure that required records are kept; and that operators at the facility are trained to respond to releases, spills, and other emergencies.

Class B operators must be trained how to meet recordkeeping and reporting requirements; ensure that equipment complies with industry standards; and train personnel to properly respond to emergencies caused by releases or spills.

By combining Class A and Class B operator training into a single test, important employee cross-training is achieved.

Course Outline

  • Chapter 1: Operator Overview
    This chapter describes the primary responsibilities of the Class A, Class B, and Class C operator. It also includes the training requirements for each class of operator.
  • Chapter 2: System and Components
    This chapter seeks to raise environmental awareness as well as clearly communicate a fundamental comprehension of UST systems. Components covered include secondary containment, emergency shut-off valves, vapor recovery, tank materials, and piping materials. A download of UST terminology is available here.
  • Chapter 3: Release Detection
    This chapter emphasizes release detection methods. Equipment testing, the analysis of test results, as well as monitoring of the UST system are addressed in this chapter. Release detection methods covered include automatic tank gauging (ATG), inventory control, secondary containment with interstitial monitoring, statistical inventory reconciliation (SIR), manual tank gauging, vacuum monitoring, soil vapor monitoring, groundwater monitoring, and tank tightness testing. Release detection methods for piping, such as electronic and manual line leak detectors, are also discussed.
  • Chapter 4: Release Prevention
    This chapter prompts the trainee to be proactive in preventing spills and releases. It covers the system components that are designed to prevent corrosion, spills, and overfills. These include spill buckets and sumps as well as sacrificial anode and impressed current cathodic systems, overfill protection valves, overfill alarms, and ball float valves. Secondary containment as well as alarms and warnings are covered in this chapter. An EPA Correct Filling Checklist is available for download.
  • Chapter 5: Planning and Response
    The focus of this chapter is preparation for a release and initial response actions. Topics include recognizing warning signs of a leak, maintaining spill kits, knowing the location of the Emergency Stop button, and posting emergency contact information. Critical attention is given to clean-up and release reporting requirements, including sensitive receptor protection and state notification requirements.
  • Chapter 6: Financial Responsibility/Financial Documents
    Owners and operators of petroleum USTs must demonstrate financial responsibility for bodily injury and property damage caused by spill and releases. This chapter covers financial responsibility statutes and financial assurance mechanisms as well as recordkeeping and reporting requirements.
  • Chapter 7: Registration and Installation
    This chapter discusses required documentation and reporting. Topics include tank permits, registration and administrative documents, and UST installation requirements.
  • Chapter 8: Inspection and Closure
    UST testing and inspection requirements are covered in this chapter. Delivery prohibition and temporary and permanent tank closures are also addressed.

End of Course Instructions

Print a copy of your completion certificate for your employer and records. You may also login and reprint your certificate at any time.

Wisconsin UST Class C Operator Training

Wisconsin Class C Operators are the first responders to emergency situations at a UST facility – like a gas station or convenience store. These individuals are usually the clerks of a facility.

Class C Operators monitor fuel deliveries to the tanks; control and/or monitor the dispensing or sale of regulated substances; and respond to alarms, releases, and other emergency situations.

Course Description

The UST Class C operator training course consists of seven chapters. Each chapter is followed by a short quiz. Once a student has completed all chapters and quizzes, the learner will be directed to print out a course checklist.

The course is instructed through a student orientation tour of a mock facility, where a manager (or Class B Operator) will identify and explain each topic and then mark them off a checklist when completed. When the checklist has been completed, the student can then print the UST Class C operator certificate.

There is not any time restriction to access the course, so students may take as much time as needed to complete their training.

Duration: 1 hour

Purpose & Objective

The purpose of the Underground Storage Tank (UST) Training Program is to protect human health and the environment by preventing future petroleum underground storage tank releases and remediating existing petroleum underground storage tank contamination.

Class C operators must be trained how to respond to emergencies (such as situations posing an immediate danger or threat to the public or to the environment and that require immediate action) and alarms caused by spills or releases from an underground storage tank system.

Course Outline

  • Chapter 1: Facility Overview
    This chapter provides a basic overview of the primary components of a typical UST facility. These components include the USTs, manways, spill buckets, fuel dispensers, and dispenser nozzles.
  • Chapter 2: Monitoring
    This chapter emphasizes the components used to monitor a UST facility. Students will learn what an Automatic Tank Gauge (ATG) is and does, how to interpret its alarms and warnings, and what to do in case of an alarm. The role of line leak detectors is also discussed.
  • Chapter 3: Environmental
    In this chapter, students learn about sensitive receptors, or places where a fuel spill may leave the facility and enter the environment. The chapter also introduces students to the spill kit and its contents, and how to use spill kit components to contain spills threatening sensitive receptors like curb breaks and drains.
  • Chapter 4: Fueling Rules
    The focus of this chapter is fuel delivery safety. Students will watch a short video on proper fueling procedures. Students also learn about hazards at the fueling point, including smoking, static electricity, leaving a vehicle unattended while fueling, and leaving a vehicle running while fueling.
  • Chapter 5: Delivery Procedures
    This chapter teaches the student how to supervise a fuel delivery and monitor for problems during a fuel delivery. Additional emphasis is placed on the ATG and on overfill prevention devices like overfill prevention valves and ball float valves. Delivery prohibitions are also addressed.
  • Chapter 6: Safety
    This chapter covers safety information every Class C Operator needs to respond to emergencies. Included here is a video explaining when and how to use a fire extinguisher. The Emergency Stop and All Stop buttons are identified and discussed.
  • Chapter 7: Emergency Situations
    This chapter discusses common emergency situations and proper responses to them, including what to do if a vehicle leaves the facility with the nozzle still in the vehicle’s fuel spout. Managing customer traffic in the event of a spill is also covered. Correct fire extinguisher operation is reviewed.
  • Chapter 8: Final Checklist
    Review and complete the checklist to complete your training

End of Course Instructions

Print a copy of your completion certificate for your employer and records. You may also login and reprint your certificate at any time.

Wisconsin UST State Agency & Regulations

The Wisconsin Department of Natural Resources (DNR) – Division of Air & Waste – Bureau of Remediation and Redevelopment/RR – Underground Storage Tank Program was created to protect human health and the environment by preventing releases of petroleum and hazardous substances from UST systems and the release of these regulated products into the environment threatens groundwater resources and can cause explosive vapors to seep into confined spaces and occupied dwellings.

Agency Link:  http://datcp.wi.gov/Consumer/Hazardous_Materials_Storage_Tanks/

UST Training in Wisconsin
The Wisconsin Department of Agriculture, Trade and Consumer Protection (DATCP) requires UST operator training includes evaluation of an operator’s knowledge of applicable requirements. Methods for meeting the requirements of Class A and B include having either of the following: (1) certificate issued by the International Code Council® showing an individual has passed the Wisconsin underground storage tank operator examination; or (2) written proof of successful completion of an equivalent, alternate operator training and testing program.

Wisconsin required every new or existing facility with an underground storage tank (UST) system must have a Class A, a Class B and a Class C operator designated by January 1, 2012. For an entity that demonstrates it meets the definition of a small business in section 227.114 (1), Stats., the date for having accredited operators is August 8, 2012.

  • Class A Operators – Manage resources and personnel, such as establishing work assignments, to achieve and maintain compliance with regulations. Ensure that appropriate individuals do all of the following: Properly operate and maintain the underground storage tank system, maintain appropriate records, receive training to operate and maintain the tank system and keep records. Properly respond to emergencies or alarms relating to spills, leaks or releases from the underground storage tank system and make financial responsibility documents available.
  • Class B Operators – Ensure that all requirements for leak or release detection methods, leak or release prevention equipment, record keeping and reporting are met. Ensure that all relevant equipment complies with performance standards and appropriate individuals are trained to properly respond to emergencies or alarms relating to spills, leaks or releases from the underground storage tank system.
  • Class C Operators – Furnish initial response to alarms, spills, leaks or releases, notify the Class B or Class A operator and appropriate emergency responders, including 911 personnel, when necessary and control or monitor the dispensing or sale of regulated substances.

The owner or operator must maintain operator documentation at the underground storage tank system site and have it immediately available for inspection by an authorized agent or the department, except for fueling facilities that are not attended as specified in section ATCP 93.605 (5) (a).

Wisconsin has not yet been granted state program approval (SPA).

Retraining Requirements
ATCP 93.880. Retraining.
If the Wisconsin Department of Agriculture, Trade and Consumer Protection (DATCP) determines that an underground storage tank system is not in significant compliance, the Class B operator must be retrained within 60 days or another time period prescribed by the Department, in the areas that are determined to not be in compliance, except both the Class A and Class B operators must be retrained if so directed by the Department.

As a result of the retraining of Class A operators or Class B operators, subsequent re-training of the Class C operators shall also occur. Voluntary refresher training is encouraged to ensure operator is up-to-date with current regulations and procedures.

References:

UST/LUST/Fund Program
Wisconsin Department of Natural Resources
Division of Air & Waste
Bureau of Remediation and Redevelopment/RR
P.O. Box 7921
Madison, WI 53707-7921

Phone: 608-267-2465
Fax: 608-267-7646

UST/LUST Program: http://dnr.wi.gov/topic/Brownfields/Petro.html

Fund Program: http://dnr.wi.gov/topic/Brownfields/pecfa.html

UST Training Course Info

Wisconsin UST Operator training courses meet federal requirements for UST training.

  • Fast and easy course completion
  • 100% online – No classroom attendance
  • No time limit – Finish at your pace
  • Certificate upon completion
  • 24×7 Online Support: Click here
  • Money Back Guarantee

Wisconsin UST Operator Training
Class A/B
  – 4hrs
Price: $150.00

Wisconsin UST Operator Training
Class C
1 hr
Price: $10.00

Training Multiple Employees?
Get volume discounts by enrolling and training all your employees. Enjoy tailored corporate solutions and training services – a free cloud-based LMS and even consulting services. Track progress, generate reports, and manage learners online. More Info

Accepted Statewide
We offer online UST Operator Training in Wisconsin for: Milwaukee, Madison, Green Bay, Kenosha, Racine, Appleton, Waukesha, Eau Claire, Oshkosh, Janesville, West Allis, La Crosse, Sheboygan, Wauwatosa, Fond du Lac, New Berlin, and many more!

Getting your Wisconsin UST Operator Training couldn’t be easier!